Murata · Japan · SIP thick film · 22 sizes

Murata MHR Series Replacement — All 22 Sizes, Cut to the Same Outline

The MHR line runs from MHR0307SA at 7.6 mm to MHR0844SA at 46 mm, all on an alumina plate with a thin blue coat and a SIP lead frame. HVC cuts the flat resistor plate on a CNC to the printed length and height and forms the lead to the same pitch, so every size in the catalogue has a 1:1 replacement.

HVC SIP thick film flat resistor replacing Murata MHR series

MHR to HVC flat resistor cross reference

Murata seriesBody L × HPitchPowerVoltage single / moldedResistanceHVC flat modelSupply
MHR0307SA series7.6 × 5 mm5.08 mm0.3 W2 / 3 kV1–1000 MΩHVRGHP5.8CNC cut to size
MHR0309SA series10.1 × 5 mm7.62 mm0.5 W3.5 / 5 kV1–1000 MΩHVRGHP5.10CNC cut to size
MHR0312SA series12.6 × 5 mm10.16 mm0.6 W5 / 7.5 kV1–1000 MΩHVRGHP5.13CNC cut to size
MHR0314SA series15.1 × 5 mm12.7 mm0.7 W6 / 10 kV1–1000 MΩHVRGHP5.15CNC cut to size
MHR0317SA series17.6 × 5 mm15.24 mm0.8 W7 / 12 kV1–1000 MΩHVRGHP5.18CNC cut to size
MHR0319SA series20.2 × 5 mm17.78 mm1 W8 / 14 kV1–2000 MΩHVRGHP5.20Catalogue outline
MHR0409SA series10.1 × 6.5 mm7.62 mm0.6 W3.5 / 10 kV1–1000 MΩHVRGHP6.10CNC cut to size
MHR0412SA series12.6 × 6.5 mm10.16 mm0.8 W5 / 10 kV1–1000 MΩHVRGHP6.13Catalogue outline
MHR0414SA series15.1 × 6.5 mm12.7 mm1 W6 / 10 kV1–1000 MΩHVRGHP6.15CNC cut to size
MHR0417SA series17.6 × 6.5 mm15.24 mm1.1 W7 / 12 kV1–2000 MΩHVRGHP6.18CNC cut to size
MHR0419SA series20.2 × 6.5 mm17.78 mm1.2 W8 / 14 kV1–2000 MΩHVRGHP6.20CNC cut to size
MHR0422SA series22.7 × 6.5 mm20.32 mm1.3 W9 / 16 kV1–2000 MΩHVRGHP6.23CNC cut to size
MHR0424SA series25.3 × 6.5 mm22.86 mm1.4 W10 / 18 kV1–2000 MΩHVRGHP6.25Catalogue outline
MHR0429SA series30.5 × 6.5 mm27.94 mm1.7 W12 / 22 kV1–2000 MΩHVRGHP6.30Catalogue outline
MHR0609SA series10.1 × 9 mm7.62 mm0.8 W3.5 / 10 kV1–1000 MΩHVRGHP9.10CNC cut to size
MHR0612SA series12.6 × 9 mm10.16 mm1 W5 / 10 kV1–2000 MΩHVRGHP9.13CNC cut to size
MHR0614SA series15.1 × 9 mm12.7 mm1.2 W6 / 12 kV1–2000 MΩHVRGHP9.15Catalogue outline
MHR0617SA series17.6 × 9 mm15.24 mm1.3 W7 / 14 kV1–2000 MΩHVRGHP9.18CNC cut to size
MHR0619SA series20.2 × 9 mm17.78 mm1.4 W8 / 16 kV1–2000 MΩHVRGHP9.20CNC cut to size
MHR0622SA series22.7 × 9 mm20.32 mm1.5 W9 / 18 kV1–10000 MΩHVRGHP9.23CNC cut to size
MHR0624SA series25.3 × 9 mm22.86 mm1.6 W10 / 20 kV1–1000 MΩHVRGHP9.25Catalogue outline
MHR0844SA series46 × 10 mm40.64 mm2.5 W20 / 35 kV1–2000 MΩHVRGHP10.46CNC cut to size

6 of the 22 sizes sit on a standard HVC outline; the remaining 16 are cut to the Murata drawing. Model codes follow the HVC flat rule HVRGHP{height}.{length}, in millimetres. Murata figures are the catalogue values; HVC ratings are continuous values in air.

Capability envelope: MHR against the other thick film lines

The MHR line is a compact SIP part, and its envelope reflects that. Set against the other thick film families a designer will shortlist for the same socket, it is the smallest on every axis.

CapabilityMurata MHRHVC HVRGHPOhmite Slim-Mox / Ultra-MoxEBG flat HV
Rated power0.3 - 2.5 W0.25 - 10 W0.25 - 9 Wup to 7.5 W
Working voltage2 - 20 kV single
3 - 35 kV molded
1.5 - 67 kV1.5 - 25 kV (Slim-Mox)
10 - 30 kV (plate)
up to 35 kV in air
Resistance1 - 2000 MΩ200 Ω - 1 TΩ100 Ω - 5 GΩ
10 TΩ on Ultra-Mox
200 Ω - 2 GΩ
TCR±250 ppm/°C maxdown to ±15 ppm/°C25 - 100 ppm/°C±80 ppm/°C
Tolerance±0.5% to ±20%±0.5% and up±0.5% and up±0.5% to ±10%
Operating temperature-40 to +125 °C-40 to +175 °C-55 to +155 °C-55 to +175 °C
PackageSIP plate, blue coatPlate, radial or SIP lead, cut to sizePlanar radialPlanar, coated

Murata figures from the MHR series datasheet R02E (TCR limit ±250 ppm/°C, Table 1). HVC figures from the HVRGHP catalogue. Ohmite figures from the Slim-Mox, Slim-Mox HT and Ultra-Mox datasheets. EBG figures from the Miba EBG flat high voltage resistor range, which states up to 35 kV in air and ±80 ppm/°C.

Three consequences follow, and they are the reason a designer arrives at this page. The MHR line stops at 2.5 W, so any divider that dissipates more has to leave the SIP footprint. It stops at 20 kV single use, so anything above that either needs the part potted or needs a different body. And at ±250 ppm/°C it is the loosest temperature coefficient in the table against a 15 ppm/°C floor, which is the figure that decides whether a divider holds its ratio in a warm cabinet.

So funktioniert der Schnitt

The MHR body is a resistor element printed on a 96 % alumina substrate, coated and fitted with a SIP lead frame. HVC builds the same construction: ruthenium oxide on alumina, laser trimmed, then CNC cut to the substrate length and height on the Murata drawing. The lead frame is formed to the printed pitch, so the part seats where the original seated and no PCB change is needed.

Because the cut is a machining step rather than a new tooling step, sizes that Murata builds in low volume, and resistance values outside the nine catalogue steps, are available without a tooling charge. That is the usual reason a buyer arrives with an MHR number rather than an order history.

Reading the two voltage columns

Every MHR size carries two figures: single use and molded use. The gap between them is the potting, not the resistor - the same substrate carries the same element. If a substitute is quoted at the molded figure without the molding, it is not the same part. State the medium (air, oil, SF6) and the duty in the enquiry.

Which sizes are worth starting from

The 5 mm and 6.5 mm substrates cover the office-machine, air purifier and static-elimination volume; the 9 mm and 10 mm substrates carry the higher wattage divider work. The power ceiling of the line is MHR0844SA at 2.5 W and 20 kV single use, so anything above that moves to the HVC GHP or PFS families rather than to a cut MHR outline.

MHR replacement FAQ

Can HVC match every MHR substrate size?

Yes. The MHR body is a thick film plate on an alumina substrate, and HVC cuts the plate on a CNC to the printed length and height, so all 22 substrate sizes in the Murata catalogue can be supplied 1:1. Six of them already sit on standard HVC outlines; the other sixteen are cut to the drawing.

Does the replacement need a different PCB layout?

No. Body length, body height and lead pitch are held to the Murata drawing, and the lead is formed to the same pitch, so the part drops into the existing footprint.

Can it be supplied with the blue coating?

Yes. The coating colour and the coating type are specified in the RFQ. Murata uses a thin blue silicone coat on the MHR line, and HVC can match it.

What about the single use and molded use voltage figures?

Murata quotes two figures because the molded version is potted. The substrate and the resistor element are the same. HVC quotes a continuous working voltage in air and reviews an oil, SF6 or potted assembly separately, so state the medium and the duty.

Every MHR size

HVC replacement for Murata MHR0307SA
MHR0307SA Serie7.6 × 5 mm · 0.3 W · 2 kV · all resistance codes
HVC replacement for Murata MHR0309SA
MHR0309SA Serie10.1 × 5 mm · 0.5 W · 3.5 kV · all resistance codes
HVC replacement for Murata MHR0312SA
MHR0312SA Serie12.6 × 5 mm · 0.6 W · 5 kV · all resistance codes
HVC replacement for Murata MHR0314SA
MHR0314SA Serie15.1 × 5 mm · 0.7 W · 6 kV · all resistance codes
HVC replacement for Murata MHR0317SA
MHR0317SA Serie17.6 × 5 mm · 0.8 W · 7 kV · all resistance codes
HVC replacement for Murata MHR0319SA
MHR0319SA Serie20.2 × 5 mm · 1 W · 8 kV · all resistance codes
HVC replacement for Murata MHR0409SA
MHR0409SA Serie10.1 × 6.5 mm · 0.6 W · 3.5 kV · all resistance codes
HVC replacement for Murata MHR0412SA
MHR0412SA Serie12.6 × 6.5 mm · 0.8 W · 5 kV · all resistance codes
HVC replacement for Murata MHR0414SA
MHR0414SA Serie15.1 × 6.5 mm · 1 W · 6 kV · all resistance codes
HVC replacement for Murata MHR0417SA
MHR0417SA Serie17.6 × 6.5 mm · 1.1 W · 7 kV · all resistance codes
HVC replacement for Murata MHR0419SA
MHR0419SA Serie20.2 × 6.5 mm · 1.2 W · 8 kV · all resistance codes
HVC replacement for Murata MHR0422SA
MHR0422SA Serie22.7 × 6.5 mm · 1.3 W · 9 kV · all resistance codes
HVC replacement for Murata MHR0424SA
MHR0424SA Serie25.3 × 6.5 mm · 1.4 W · 10 kV · all resistance codes
HVC replacement for Murata MHR0429SA
MHR0429SA Serie30.5 × 6.5 mm · 1.7 W · 12 kV · all resistance codes
HVC replacement for Murata MHR0609SA
MHR0609SA Serie10.1 × 9 mm · 0.8 W · 3.5 kV · all resistance codes
HVC replacement for Murata MHR0612SA
MHR0612SA Serie12.6 × 9 mm · 1 W · 5 kV · all resistance codes
HVC replacement for Murata MHR0614SA
MHR0614SA Serie15.1 × 9 mm · 1.2 W · 6 kV · all resistance codes
HVC replacement for Murata MHR0617SA
MHR0617SA Serie17.6 × 9 mm · 1.3 W · 7 kV · all resistance codes
HVC replacement for Murata MHR0619SA
MHR0619SA Serie20.2 × 9 mm · 1.4 W · 8 kV · all resistance codes
HVC replacement for Murata MHR0622SA
MHR0622SA Serie22.7 × 9 mm · 1.5 W · 9 kV · all resistance codes
HVC replacement for Murata MHR0624SA
MHR0624SA Serie25.3 × 9 mm · 1.6 W · 10 kV · all resistance codes
HVC replacement for Murata MHR0844SA
MHR0844SA Serie46 × 10 mm · 2.5 W · 20 kV · all resistance codes

Auf dieser Seite verwendete HVC-Familie: GHP flat-style plate resistor.

Technisches Angebot / Reaktionszeit innerhalb von 6 Stunden

SCHICKEN SIE UNS DIE SPEZIFIKATION. WIR KÜMMERN UNS UM DIE ZUGEWÄHLTEN TEILE.

Senden Sie uns eine Teilenummer, eine Zeichnung, ein Datenblatt oder eine Stückliste. HVC Sales & Engineering wird Ihnen anschließend einen passenden Produktweg und ein Angebot unterbreiten.

Technisches Angebot anfordern