HVCA| Part Number | HVC Alternative | VRRM | IO | Trr |
|---|---|---|---|---|
| DV6P | HVD-SL6G75 | 6KV | 75mA | 75ns |
| DV8P | HVD-SL8G60 | 8KV | 60mA | 75ns |
| DV10P | HVD-SL10G55 | 10KV | 55mA | 75ns |
| G6FS | HVD-SL6G25 | 6KV | 25mA | 100ns |
| G7FS | HVD-SL7G25 | 7KV | 25mA | 100ns |
| G8FS | HVD-SL8G25 | 8KV | 25mA | 100ns |
| G10FS | HVD-SL10G25 | 10KV | 25mA | 100ns |
| G12FS | HVD-SL12G25 | 12KV | 25mA | 100ns |
| G15FS | HVD-SL15G25 | 15KV | 25mA | 100ns |
| G20FS | HVD-SL20G25 | 20KV | 25mA | 100ns |
| G25FS | HVD-SL25G25 | 25KV | 25mA | 100ns |
| G30FS | HVD-SL30G25 | 30KV | 25mA | 100ns |
| G2FSA | HVD-SL2G25 | 2KV | 25mA | 75ns |
| G3FSA | HVD-SL3G25 | 3KV | 25mA | 75ns |
| G4FSA | HVD-SL4G25 | 4KV | 25mA | 75ns |
| G5FSA | HVD-SL5G25 | 5KV | 25mA | 75ns |
| HL300 | HVD-SL3G40 | 3KV | 40mA | 100ns |
| HL500 | HVD-SL5G40 | 5KV | 40mA | 100ns |
| HL800 | HVD-SL8G40 | 8KV | 40mA | 100ns |
| HL1000 | HVD-SL10G40 | 10KV | 40mA | 100ns |
| HL1200 | HVD-SL12G40 | 12KV | 40mA | 100ns |
| HVEF8P | — | 8KV | 30mA | 20ns |
| HVEF10P | — | 10KV | 20mA | 20ns |
| HVEF12P | — | 12KV | 20mA | 20ns |
| NV20FP | HVD-SL2G20 | 2KV | 20mA | 80ns |
| NV30FP | HVD-SL3G20 | 3KV | 20mA | 80ns |
| NV40FP | HVD-SL4G20 | 4KV | 20mA | 80ns |
| NV50FP | HVD-SL5G20 | 5KV | 20mA | 80ns |
| HVRT080 | HVD-SL8G30 | 8KV | 30mA | 100ns |
| HVRT120 | HVD-SL12G30 | 12KV | 30mA | 100ns |
| HVRT150 | HVD-SL15G30 | 15KV | 30mA | 100ns |
| HVRT200 | HVD-SL20G30 | 20KV | 30mA | 100ns |
| HVRT250 | HVD-SL25G30 | 25KV | 30mA | 100ns |
| HVRT300 | HVD-SL30G30 | 30KV | 30mA | 100ns |
| HVRL150 | HVD-SL15G30 | 15KV | 30mA | 100ns |
| HVRL200 | HVD-SL20G30 | 20KV | 30mA | 100ns |
| HVRL250 | HVD-SL25G30 | 25KV | 30mA | 100ns |
| HVRL300 | HVD-SL30G30 | 30KV | 30mA | 100ns |
| HVRL400 | HVD-SL40G30 | 40KV | 30mA | 100ns |
| HV07-12B | HVD-SL312 | 12KV | 225mA | / |
| HV37-08 | HVD-SL308G | 8KV | 210mA | 150ns |
| HV37-08F | HVD-SL208G | 8KV | 210mA | 50ns |
| HV37-10 | HVD-SL310G | 10KV | 190mA | 150ns |
| HV37-10F | HVD-SL310GF | 10KV | 190mA | 120ns |
| HV37-12 | HVD-SL312G | 12KV | 250mA | 100ns |
| HV37-12F | HVD-SL312GF | 12KV | 300mA | 80ns |
| HV37-20 | HVD-SL220G | 20KV | 200mA | 100ns |
| HV37-20F | HVD-SL220GF | 20KV | 200mA | 80ns |
| CL03-08 | HVD-SL03-08 | 8KV | 400mA | 100ns |
| CL03-10 | HVD-SL03-10 | 10KV | 300mA | 100ns |
| CL03-12 | HVD-SL03-12 | 12KV | 250mA | 100ns |
| CL03-15 | HVD-SL03-15 | 15KV | 200mA | 100ns |
| CL03-20 | HVD-SL03-20 | 20KV | 120mA | 100ns |
| CL03-30 | HVD-SL03-30 | 30KV | 120mA | 100ns |
| 2CL2FF | HVD-2CL2FF | 8KV | 60mA | 150ns |
| 2CL2F | HVD-2CL2F | 8KV | 100mA | / |
| 2CL2FG | HVD-2CL2FG | 10KV | 60mA | 150ns |
| 2CL2G | HVD-2CL2G | 10KV | 100mA | / |
| 2CL2FK | HVD-2CL2FK | 10KV | 140mA | 100ns |
| 2CL2FH | HVD-2CL2FH | 12KV | 60mA | 150ns |
| 2CL2H | HVD-2CL2H | 12KV | 100mA | / |
| 2CL2FJ | HVD-2CL2FJ | 15KV | 60mA | 150ns |
| 2CL2J | HVD-2CL2J | 15KV | 100mA | / |
| 2CL2FL | HVD-2CL2FL | 15KV | 120mA | 100ns |
| 2CL2FM | HVD-2CL2FM | 20KV | 100mA | / |
| 2CL2FP | HVD-2CL2FP | 30KV | 140mA | 100ns |
| 2CL2FR | HVD-2CL2FR | 35KV | 100mA | 100ns |
| 2CL105 | HVD-2CL105 | 9KV | 450mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450mA | / |
| UX-FBR8 | HVD-2CL8KV / 420 mA | 8KV | 420mA | / |
| UX-F2CL15 | HVD-2CLG15KV / 150 mA | 15KV | 150mA | 50ns |
| UX-F15B | HVD-2CLG15KV / 200 mA | 15KV | 200mA | 50ns |
| UX-F30B | HVD-2CLG30KV / 100 mA | 30KV | 100mA | 50ns |
| 2CL105 | HVD-2CL105 | 9KV | 450mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450mA | / |
| BR2F | HVD-SL2F | 2KV | 900mA | 100ns |
| BR2 | HVD-SL2 | 2KV | 1000mA | / |
| BR3F | HVD-SL3F | 3KV | 900mA | 100ns |
| BR4F | HVD-SL4F | 4KV | 600mA | 100ns |
| BR4 | HVD-SL4 | 4KV | 850mA | / |
| BR5F | HVD-SL5F | 5KV | 600mA | 100ns |
| BR6F | HVD-SL6F | 6KV | 500mA | 100ns |
| BR8F | HVD-SL8F | 8KV | 400mA | 100ns |
| BR10F | HVD-SL10F | 10KV | 250mA | 100ns |
| BRU10SF | HVD-SLU10SF | 10KV | 250mA | 75ns |
| HV200UF3 | HVD-SL200UF3 | 3KV | 375mA | 50ns |
| HV200UF4 | HVD-SL200UF4 | 4KV | 375mA | 50ns |
| HV200UF5 | HVD-SL200UF5 | 5KV | 375mA | 50ns |
| HV550S08 | HVD-HV600S08 | 8KV | 550mA | / |
| HV550S10 | HVD-HV600S10 | 10KV | 450mA | / |
| HV550S12 | HVD-HV600S12 | 12KV | 400mA | / |
| HV550S15 | HVD-HV600S15 | 15KV | 350mA | / |
| HV550S20 | HVD-HV600S20 | 20KV | 250mA | / |
| HV550S25 | HVD-HV600S25 | 25KV | 200mA | / |
| HV550S30 | HVD-HV600S30 | 30KV | 200mA | / |
| HV550S45 | HVD-HV600S45 | 45KV | 100mA | / |
| HVCF25 | HVD-2CLG2.5KV / 1.5A | 2.5KV | 1500mA | 75ns |
| HVCF50 | HVD-2CLG5KV / 1.2A | 5KV | 1200mA | 75ns |
| HVCF100 | HVD-2CLG10KV / 0.65A | 10KV | 650mA | 75ns |
| HVRW1 | HVD-HVRW1 | 1KV | 2500mA | 150ns |
| HVRW2 | HVD-HVRW2 | 2KV | 1500mA | 150ns |
| HVRW3 | HVD-HVRW3 | 3KV | 1500mA | 150ns |
| HVRW4 | HVD-HVRW4 | 4KV | 1000mA | 150ns |
| HVW3 | HVD-HVRM3 | 3KV | 2000mA | / |
| UFHV2K | HVD-SL2G550 | 2KV | 550mA | 75ns |
| UFHV3K | HVD-SL3G400 | 3KV | 400mA | 75ns |
| UFHV4K | HVD-SL4G350 | 4KV | 350mA | 75ns |
| EF100 | HVD-SLF100 | 1KV | 600mA | / |
| EF150 | HVD-SLF150 | 1.5KV | 600mA | / |
| EF200 | HVD-SLF200 | 2KV | 600mA | / |
| EG200 | HVD-SLG200 | 2KV | 400mA | / |
| EG250 | HVD-SLG250 | 2.5KV | 400mA | / |
| EG300 | HVD-SLG300 | 3KV | 400mA | / |
| EH300 | HVD-SLH300 | 3KV | 300mA | / |
| EH350 | HVD-SLH350 | 3.5KV | 300mA | / |
| EH400 | HVD-SLH400 | 4KV | 300mA | / |
| EK450 | HVD-SLH450 | 4.5KV | 200mA | / |
| EK500 | HVD-SLH500 | 5KV | 200mA | / |
| EK600 | HVD-SLH600 | 6KV | 200mA | / |
| EM700 | HVD-SLM700 | 7KV | 175mA | / |
| EM800 | HVD-SLM800 | 8KV | 175mA | / |
| EP900 | — | 9KV | 150mA | / |
| EP1000 | — | 10KV | 150mA | / |
| ER1100 | HVD-SLP1100 | 11KV | 100mA | / |
| ER1200 | HVD-SLP1200 | 12KV | 100mA | / |
| RF160B | HVD-SLF160B | 1.6KV | 500mA | 250ns |
| RF200B | HVD-SLF200B | 2KV | 500mA | 250ns |
| RG300B | HVD-SLG300B | 3KV | 350mA | 250ns |
| RK300B | HVD-SLK300B | 3KV | 150mA | 250ns |
| RK400B | HVD-SLK400B | 4KV | 150mA | 250ns |
| RK500B | HVD-SLK500B | 5KV | 150mA | 250ns |
| RK600B | HVD-SLK600B | 6KV | 150mA | 250ns |
| RM700B | HVD-SLM700B | 7KV | 125mA | 250ns |
| RM800B | HVD-SLM800B | 8KV | 125mA | 250ns |
| RP900B | HVD-SLP900B | 9KV | 100mA | 250ns |
| RP1000B | HVD-SLP1000B | 10KV | 100mA | 250ns |
| RR1100B | HVD-SLP1100B | 11KV | 80mA | 250ns |
| RR1200B | HVD-SLP1200B | 12KV | 80mA | 250ns |
| RF160A | HVD-SLF160A | 1.6KV | 500mA | 150ns |
| RF200A | HVD-SLF200A | 2KV | 500mA | 150ns |
| RG300A | HVD-SLG300A | 3KV | 350mA | 150ns |
| RK300A | HVD-SLK300A | 3KV | 150mA | 150ns |
| RK400A | HVD-SLK400A | 4KV | 150mA | 150ns |
| RK500A | HVD-SLK500A | 5KV | 150mA | 150ns |
| RK600A | HVD-SLK600A | 6KV | 150mA | 150ns |
| RM800A | HVD-SLM800A | 8KV | 125mA | 150ns |
| RP1000A | HVD-SLP1000A | 10KV | 100mA | 150ns |
| RR1200A | HVD-SLR100A | 12KV | 80mA | 150ns |
| FB4 | HVD-SL4 | 4KV | 2A | / |
| FB5 | HVD-SL5 | 5KV | 2A | / |
| FBR3 | HVD-SLR3 | 3KV | 1.5A | 250ns |
| FBR3.5 | HVD-SLR3.5 | 3.5KV | 1.5A | 250ns |
| FBR4 | HVD-SLR4 | 4KV | 1.5A | 250ns |
| 3W2 | HVD-HVRM2 | 2KV | 2A | / |
| 3W2.5 | HVD-HVRM2.5 | 2.5KV | 2A | / |
| 3W3 | HVD-HVRM3 | 3KV | 2A | / |
| 3RW2 | HVD-HVRW2 | 2KV | 1.5A | 250ns |
| 3RW2.5 | HVD-HVRW2.5 | 2.5KV | 1.5A | 250ns |
| 3RW3 | HVD-HVRW3 | 3KV | 1.5A | 250ns |
| XL10 | HVD-SL10 | 9KV | 220mA | / |
| XLR5 | HVD-SLR5 | 5KV | 200mA | 175ns |
| XLR10 | HVD-SLR10 | 9KV | 200mA | 175ns |
| XLU12 | HVD-SLU12 | 11KV | 100mA | 50ns |
| XLR20 | HVD-SLR20 | 18KV | 100mA | 175ns |
| XMR5 | — | 5KV | 500mA | 150ns |
| XMU5 | HVD-SLMU5 | 5KV | 300mA | 75ns |
| XMU10 | HVD-SLMU10 | 9KV | 300mA | 75ns |
| DR300 | HVD-SL3G25 | 3KV | 25mA | 100ns |
| DR500 | HVD-SL5G25 | 5KV | 25mA | 100ns |
| DR800 | HVD-SL8G25 | 8KV | 25mA | 100ns |
| DR1000 | HVD-SL10G25 | 10KV | 25mA | 100ns |
| DR1200 | HVD-SL12G25 | 12KV | 25mA | 100ns |
| DR1500 | HVD-SL15G25 | 15KV | 25mA | 100ns |
| DL300 | HVD-SL3G25 | 3KV | 25mA | 150ns |
| DL500 | HVD-SL5G25 | 5KV | 25mA | 150ns |
| DL800 | HVD-SL8G25 | 8KV | 25mA | 150ns |
| DL1000 | HVD-SL10G25 | 10KV | 25mA | 150ns |
| DL1200 | HVD-SL12G25 | 12KV | 25mA | 150ns |
| QR12 | HVD-2CL73 | 12KV | 6mA | 100ns |
| TV6 | HVD-2CL70 | 6KV | 5mA | 100ns |
| TV8 | HVD-2CL71 | 8KV | 5mA | 100ns |
| TV10 | HVD-2CL72 | 10KV | 5mA | 100ns |
| TV12 | HVD-2CL73 | 12KV | 5mA | 100ns |
| TV14 | HVD-2CL74 | 14KV | 5mA | 100ns |
| TV16 | HVD-2CL75 | 16KV | 5mA | 100ns |
| TV20 | HVD-2CL77 | 20KV | 5mA | 100ns |
| TVR30 | HVD-2CL82 | 30KV | 10mA | 100ns |
| RUSH103 | HVD-SL200UF3 | 3KV | 200mA | 50ns |
| RUSH104 | HVD-SL200UF4 | 4KV | 200mA | 50ns |
| RUSH105 | HVD-SL200UF5 | 5KV | 200mA | 50ns |
| VT1000 | HVD-SL1000 | 10KV | 50mA | / |
| VT1200 | HVD-SL1200 | 12KV | 50mA | / |
| VT1500 | HVD-SL1500 | 15KV | 50mA | / |
| RVT1000 | HVD-SL10G50 | 10KV | 50mA | 100ns |
| RVT1200 | HVD-SL12G50 | 12KV | 50mA | 100ns |
| RVT1500 | HVD-SL15G50 | 15KV | 50mA | 100ns |
| RUST2008 | — | 8KV | 100mA | 50ns |
| RUST2010 | — | 10KV | 100mA | 50ns |
| CRVT150 | HVD-SL15G25B | 15KV | 25mA | 100ns |
| CRVT200 | HVD-SL20G25B | 20KV | 25mA | 100ns |
| CRVT250 | HVD-SL25G25B | 25KV | 25mA | 100ns |
| CRVT300 | HVD-SL30G25B | 30KV | 25mA | 100ns |
| SL300 | HVD-SL3G40 | 3KV | 40mA | 100ns |
| SL500 | HVD-SL5G40 | 5KV | 40mA | 100ns |
| SL800 | HVD-SL8G40 | 8KV | 40mA | 100ns |
| SL1000 | HVD-SL10G40 | 10KV | 40mA | 100ns |
| SL1200 | HVD-SL12G40 | 12KV | 40mA | 100ns |
| SR300 | HVD-SL3G25 | 3KV | 25mA | 100ns |
| SR500 | HVD-SL5G25 | 5KV | 25mA | 100ns |
| SR800 | HVD-SL8G25 | 8KV | 25mA | 100ns |
| SR1000 | HVD-SL10G25 | 10KV | 25mA | 100ns |
| SR1200 | HVD-SL12G25 | 12KV | 25mA | 100ns |
| SR1500 | HVD-SL15G25 | 15KV | 25mA | 100ns |
| 2CL69 | HVD-2CL69 | 4KV | 5mA | 100ns |
| 2CL70 | HVD-2CL70 | 6KV | 5mA | 100ns |
| 2CL71 | HVD-2CL71 | 8KV | 5mA | 100ns |
| 2CL72 | HVD-2CL72 | 10KV | 5mA | 100ns |
| 2CL73 | HVD-2CL73 | 12KV | 5mA | 100ns |
| 2CL74 | HVD-2CL74 | 14KV | 5mA | 100ns |
| 2CL75 | HVD-2CL75 | 16KV | 5mA | 100ns |
| 2CL76 | HVD-2CL76 | 18KV | 5mA | 100ns |
| 2CL77 | HVD-2CL77 | 20KV | 5mA | 100ns |
| 2CL103 | HVD-2CL103 | 9KV | 350mA | / |
| 2CL104 | HVD-2CL104 | 12KV | 350mA | / |
| 2CL105 | HVD-2CL105 | 9KV | 450mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450mA | / |
| R3000 | HVD-R3000 | 3KV | 200mA | / |
| R3000F | HVD-R3000F | 3KV | 200mA | / |
| R4000 | HVD-R4000 | 4KV | 200mA | / |
| R4000F | HVD-R4000F | 4KV | 200mA | / |
| R5000 | — | 5KV | 200mA | / |
| R5000F | HVD-R5000F | 5KV | 200mA | / |
| RFC3K | HVD-R3000 | 3KV | 200mA | / |
| RFC4K | HVD-R4000 | 4KV | 200mA | / |
| 2CL4 | HVD-2CL69 | 4KV | 5mA | 100ns |
| 2CL6 | HVD-2CL70 | 6KV | 5mA | 100ns |
| 2CL8 | HVD-2CL71 | 8KV | 5mA | 100ns |
| 2CL10 | HVD-2CL72 | 10KV | 5mA | 100ns |
| 2CL12 | HVD-2CL73 | 12KV | 5mA | 100ns |
| 2CL14 | HVD-2CL74 | 14KV | 5mA | 100ns |
| 2CL16 | HVD-2CL75 | 16KV | 5mA | 100ns |
| 2CL20 | HVD-2CL77 | 20KV | 5mA | 100ns |
| 2CL703 | HVD-2CL703 | 3KV | 5mA | 80ns |
| 2CL704 | HVD-2CL704 | 4KV | 5mA | 80ns |
| T71A | HVD-2CLT71 | 8KV | 5mA | 80ns |
| T72A | HVD-2CLT72 | 10KV | 5mA | 80ns |
| T73A | HVD-2CLT73 | 12KV | 5mA | 80ns |
| T74A | HVD-2CLT74 | 14KV | 5mA | 80ns |
| T75A | HVD-2CLT75 | 16KV | 5mA | 80ns |
| TG3508 | HVD-SL3508G | 8KV | 350mA | 150ns |
| TS01 | HVD-SL3506 | 6KV | 350mA | / |
| UX-C2B | — | 8KV | 500mA | 35ns |
| T3512H | HVD-2CL3512 | 12KV | 350mA | / |
| T4512H | HVD-2CL4512 | 12KV | 450mA | / |
| T3509 | HVD-2CL3509 | 9KV | 350mA | / |
| T4509 | HVD-2CL4509 | 9KV | 450mA | / |
| 2CL3512H | HVD-2CL3512 | 12KV | 350mA | / |
| 2CL4512H | HVD-2CL4512 | 12KV | 450mA | / |
| BR2 | HVD-SL2 | 2KV | 1000mA | / |
| BR4 | HVD-SL4 | 4KV | 1000mA | / |
| TG1015 | HVD-2CL15KV / 100 mA | 15KV | 100mA | 150ns |
| SHV049 | HVD-2CL15KV / 100 mA | 15KV | 100mA | 150ns |
| 2CLG1015 | HVD-2CL15KV / 100 mA | 15KV | 100mA | 150ns |
| DD2000 | HVD-SL30F10 | 30KV | 10mA | / |
| JB99 | HVD-2CL20KV / 20 mA | 20KV | 20mA | 100ns |
| JB99T | HVD-2CL20KV / 20 mA | 20KV | 20mA | 100ns |
| DV6P | HVD-SL6G75 | 6KV | 75mA | 75ns |
| DV8P | HVD-SL8G60 | 8KV | 60mA | 75ns |
| DV10P | HVD-SL10G55 | 10KV | 55mA | 75ns |
| G6FS | HVD-SL6G25 | 6KV | 25mA | 100ns |
| G7FS | HVD-SL7G25 | 7KV | 25mA | 100ns |
| G8FS | HVD-SL8G25 | 8KV | 25mA | 100ns |
| G10FS | HVD-SL10G25 | 10KV | 25mA | 100ns |
| G12FS | HVD-SL12G25 | 12KV | 25mA | 100ns |
| G15FS | HVD-SL15G25 | 15KV | 25mA | 100ns |
| G20FS | HVD-SL20G25 | 20KV | 25mA | 100ns |
| G25FS | HVD-SL25G25 | 25KV | 25mA | 100ns |
| G30FS | HVD-SL30G25 | 30KV | 25mA | 100ns |
| G2FSA | HVD-SL2G25 | 2KV | 25mA | 75ns |
| G3FSA | HVD-SL3G25 | 3KV | 25mA | 75ns |
| G4FSA | HVD-SL4G25 | 4KV | 25mA | 75ns |
| G5FSA | HVD-SL5G25 | 5KV | 25mA | 75ns |
| HL300 | HVD-SL3G40 | 3KV | 40mA | 100ns |
| HL500 | HVD-SL5G40 | 5KV | 40mA | 100ns |
| HL800 | HVD-SL8G40 | 8KV | 40mA | 100ns |
| HL1000 | HVD-SL10G40 | 10KV | 40mA | 100ns |
| HL1200 | HVD-SL12G40 | 12KV | 40mA | 100ns |
| HVEF8P | — | 8KV | 30mA | 20ns |
| HVEF10P | — | 10KV | 20mA | 20ns |
| HVEF12P | — | 12KV | 20mA | 20ns |
| NV20FP | HVD-SL2G20 | 2KV | 20mA | 80ns |
| NV30FP | HVD-SL3G20 | 3KV | 20mA | 80ns |
| NV40FP | HVD-SL4G20 | 4KV | 20mA | 80ns |
| NV50FP | HVD-SL5G20 | 5KV | 20mA | 80ns |
| HVRT080 | HVD-SL8G30 | 8KV | 30mA | 100ns |
| HVRT120 | HVD-SL12G30 | 12KV | 30mA | 100ns |
| HVRT150 | HVD-SL15G30 | 15KV | 30mA | 100ns |
| HVRT200 | HVD-SL20G30 | 20KV | 30mA | 100ns |
| HVRT250 | HVD-SL25G30 | 25KV | 30mA | 100ns |
| HVRT300 | HVD-SL30G30 | 30KV | 30mA | 100ns |
| HVRL150 | HVD-SL15G30 | 15KV | 30mA | 100ns |
| HVRL200 | HVD-SL20G30 | 20KV | 30mA | 100ns |
| HVRL250 | HVD-SL25G30 | 25KV | 30mA | 100ns |
| HVRL300 | HVD-SL30G30 | 30KV | 30mA | 100ns |
| HVRL400 | HVD-SL40G30 | 40KV | 30mA | 100ns |
| HV07-12B | HVD-SL312 | 12KV | 225mA | / |
| HV37-08 | HVD-SL308G | 8KV | 210mA | 150ns |
| HV37-08F | HVD-SL208G | 8KV | 210mA | 50ns |
| HV37-10 | HVD-SL310G | 10KV | 190mA | 150ns |
| HV37-10F | HVD-SL310GF | 10KV | 190mA | 120ns |
| HV37-12 | HVD-SL312G | 12KV | 250mA | 100ns |
| HV37-12F | HVD-SL312GF | 12KV | 300mA | 80ns |
| HV37-20 | HVD-SL220G | 20KV | 200mA | 100ns |
| HV37-20F | HVD-SL220GF | 20KV | 200mA | 80ns |
| CL03-08 | HVD-SL03-08 | 8KV | 400mA | 100ns |
| CL03-10 | HVD-SL03-10 | 10KV | 300mA | 100ns |
| CL03-12 | HVD-SL03-12 | 12KV | 250mA | 100ns |
| CL03-15 | HVD-SL03-15 | 15KV | 200mA | 100ns |
| CL03-20 | HVD-SL03-20 | 20KV | 120mA | 100ns |
| CL03-30 | HVD-SL03-30 | 30KV | 120mA | 100ns |
| 2CL2FF | HVD-2CL2FF | 8KV | 60mA | 150ns |
| 2CL2F | HVD-2CL2F | 8KV | 100mA | / |
| 2CL2FG | HVD-2CL2FG | 10KV | 60mA | 150ns |
| 2CL2G | HVD-2CL2G | 10KV | 100mA | / |
| 2CL2FK | HVD-2CL2FK | 10KV | 140mA | 100ns |
| 2CL2FH | HVD-2CL2FH | 12KV | 60mA | 150ns |
| 2CL2H | HVD-2CL2H | 12KV | 100mA | / |
| 2CL2FJ | HVD-2CL2FJ | 15KV | 60mA | 150ns |
| 2CL2J | HVD-2CL2J | 15KV | 100mA | / |
| 2CL2FL | HVD-2CL2FL | 15KV | 120mA | 100ns |
| 2CL2FM | HVD-2CL2FM | 20KV | 100mA | / |
| 2CL2FP | HVD-2CL2FP | 30KV | 140mA | 100ns |
| 2CL2FR | HVD-2CL2FR | 35KV | 100mA | 100ns |
| 2CL105 | HVD-2CL105 | 9KV | 450mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450mA | / |
| UX-FBR8 | HVD-2CL8KV / 420 mA | 8KV | 420mA | / |
| UX-F2CL15 | HVD-2CLG15KV / 150 mA | 15KV | 150mA | 50ns |
| UX-F15B | HVD-2CLG15KV / 200 mA | 15KV | 200mA | 50ns |
| UX-F30B | HVD-2CLG30KV / 100 mA | 30KV | 100mA | 50ns |
| 2CL105 | HVD-2CL105 | 9KV | 450mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450mA | / |
| BR2F | HVD-SL2F | 2KV | 900mA | 100ns |
| BR2 | HVD-SL2 | 2KV | 1000mA | / |
| BR3F | HVD-SL3F | 3KV | 900mA | 100ns |
| BR4F | HVD-SL4F | 4KV | 600mA | 100ns |
| BR4 | HVD-SL4 | 4KV | 850mA | / |
| BR5F | HVD-SL5F | 5KV | 600mA | 100ns |
| BR6F | HVD-SL6F | 6KV | 500mA | 100ns |
| BR8F | HVD-SL8F | 8KV | 400mA | 100ns |
| BR10F | HVD-SL10F | 10KV | 250mA | 100ns |
| BRU10SF | HVD-SLU10SF | 10KV | 250mA | 75ns |
| HV200UF3 | HVD-SL200UF3 | 3KV | 375mA | 50ns |
| HV200UF4 | HVD-SL200UF4 | 4KV | 375mA | 50ns |
| HV200UF5 | HVD-SL200UF5 | 5KV | 375mA | 50ns |
| HV550S08 | HVD-HV600S08 | 8KV | 550mA | / |
| HV550S10 | HVD-HV600S10 | 10KV | 450mA | / |
| HV550S12 | HVD-HV600S12 | 12KV | 400mA | / |
| HV550S15 | HVD-HV600S15 | 15KV | 350mA | / |
| HV550S20 | HVD-HV600S20 | 20KV | 250mA | / |
| HV550S25 | HVD-HV600S25 | 25KV | 200mA | / |
| HV550S30 | HVD-HV600S30 | 30KV | 200mA | / |
| HV550S45 | HVD-HV600S45 | 45KV | 100mA | / |
| HVCF25 | HVD-2CLG2.5KV / 1.5A | 2.5KV | 1500mA | 75ns |
| HVCF50 | HVD-2CLG5KV / 1.2A | 5KV | 1200mA | 75ns |
| HVCF100 | HVD-2CLG10KV / 0.65A | 10KV | 650mA | 75ns |
| HVRW1 | HVD-HVRW1 | 1KV | 2500mA | 150ns |
| HVRW2 | HVD-HVRW2 | 2KV | 1500mA | 150ns |
| HVRW3 | HVD-HVRW3 | 3KV | 1500mA | 150ns |
| HVRW4 | HVD-HVRW4 | 4KV | 1000mA | 150ns |
| HVW3 | HVD-HVRM3 | 3KV | 2000mA | / |
| UFHV2K | HVD-SL2G550 | 2KV | 550mA | 75ns |
| UFHV3K | HVD-SL3G400 | 3KV | 400mA | 75ns |
| UFHV4K | HVD-SL4G350 | 4KV | 350mA | 75ns |
| EF100 | HVD-SLF100 | 1KV | 600mA | / |
| EF150 | HVD-SLF150 | 1.5KV | 600mA | / |
| EF200 | HVD-SLF200 | 2KV | 600mA | / |
| EG200 | HVD-SLG200 | 2KV | 400mA | / |
| EG250 | HVD-SLG250 | 2.5KV | 400mA | / |
| EG300 | HVD-SLG300 | 3KV | 400mA | / |
| EH300 | HVD-SLH300 | 3KV | 300mA | / |
| EH350 | HVD-SLH350 | 3.5KV | 300mA | / |
| EH400 | HVD-SLH400 | 4KV | 300mA | / |
| EK450 | HVD-SLH450 | 4.5KV | 200mA | / |
| EK500 | HVD-SLH500 | 5KV | 200mA | / |
| EK600 | HVD-SLH600 | 6KV | 200mA | / |
| EM700 | HVD-SLM700 | 7KV | 175mA | / |
| EM800 | HVD-SLM800 | 8KV | 175mA | / |
| EP900 | — | 9KV | 150mA | / |
| EP1000 | — | 10KV | 150mA | / |
| ER1100 | HVD-SLP1100 | 11KV | 100mA | / |
| ER1200 | HVD-SLP1200 | 12KV | 100mA | / |
| RF160B | HVD-SLF160B | 1.6KV | 500mA | 250ns |
| RF200B | HVD-SLF200B | 2KV | 500mA | 250ns |
| RG300B | HVD-SLG300B | 3KV | 350mA | 250ns |
| RK300B | HVD-SLK300B | 3KV | 150mA | 250ns |
| RK400B | HVD-SLK400B | 4KV | 150mA | 250ns |
| RK500B | HVD-SLK500B | 5KV | 150mA | 250ns |
| RK600B | HVD-SLK600B | 6KV | 150mA | 250ns |
| RM700B | HVD-SLM700B | 7KV | 125mA | 250ns |
| RM800B | HVD-SLM800B | 8KV | 125mA | 250ns |
| RP900B | HVD-SLP900B | 9KV | 100mA | 250ns |
| RP1000B | HVD-SLP1000B | 10KV | 100mA | 250ns |
| RR1100B | HVD-SLP1100B | 11KV | 80mA | 250ns |
| RR1200B | HVD-SLP1200B | 12KV | 80mA | 250ns |
| RF160A | HVD-SLF160A | 1.6KV | 500mA | 150ns |
| RF200A | HVD-SLF200A | 2KV | 500mA | 150ns |
| RG300A | HVD-SLG300A | 3KV | 350mA | 150ns |
| RK300A | HVD-SLK300A | 3KV | 150mA | 150ns |
| RK400A | HVD-SLK400A | 4KV | 150mA | 150ns |
| RK500A | HVD-SLK500A | 5KV | 150mA | 150ns |
| RK600A | HVD-SLK600A | 6KV | 150mA | 150ns |
| RM800A | HVD-SLM800A | 8KV | 125mA | 150ns |
| RP1000A | HVD-SLP1000A | 10KV | 100mA | 150ns |
| RR1200A | HVD-SLR100A | 12KV | 80mA | 150ns |
| FB4 | HVD-SL4 | 4KV | 2A | / |
| FB5 | HVD-SL5 | 5KV | 2A | / |
| FBR3 | HVD-SLR3 | 3KV | 1.5A | 250ns |
| FBR3.5 | HVD-SLR3.5 | 3.5KV | 1.5A | 250ns |
| FBR4 | HVD-SLR4 | 4KV | 1.5A | 250ns |
| 3W2 | HVD-HVRM2 | 2KV | 2A | / |
| 3W2.5 | HVD-HVRM2.5 | 2.5KV | 2A | / |
| 3W3 | HVD-HVRM3 | 3KV | 2A | / |
| 3RW2 | HVD-HVRW2 | 2KV | 1.5A | 250ns |
| 3RW2.5 | HVD-HVRW2.5 | 2.5KV | 1.5A | 250ns |
| 3RW3 | HVD-HVRW3 | 3KV | 1.5A | 250ns |
| XL10 | HVD-SL10 | 9KV | 220mA | / |
| XLR5 | HVD-SLR5 | 5KV | 200mA | 175ns |
| XLR10 | HVD-SLR10 | 9KV | 200mA | 175ns |
| XLU12 | HVD-SLU12 | 11KV | 100mA | 50ns |
| XLR20 | HVD-SLR20 | 18KV | 100mA | 175ns |
| XMR5 | — | 5KV | 500mA | 150ns |
| XMU5 | HVD-SLMU5 | 5KV | 300mA | 75ns |
| XMU10 | HVD-SLMU10 | 9KV | 300mA | 75ns |
| DR300 | HVD-SL3G25 | 3KV | 25mA | 100ns |
| DR500 | HVD-SL5G25 | 5KV | 25mA | 100ns |
| DR800 | HVD-SL8G25 | 8KV | 25mA | 100ns |
| DR1000 | HVD-SL10G25 | 10KV | 25mA | 100ns |
| DR1200 | HVD-SL12G25 | 12KV | 25mA | 100ns |
| DR1500 | HVD-SL15G25 | 15KV | 25mA | 100ns |
| DL300 | HVD-SL3G25 | 3KV | 25mA | 150ns |
| DL500 | HVD-SL5G25 | 5KV | 25mA | 150ns |
| DL800 | HVD-SL8G25 | 8KV | 25mA | 150ns |
| DL1000 | HVD-SL10G25 | 10KV | 25mA | 150ns |
| DL1200 | HVD-SL12G25 | 12KV | 25mA | 150ns |
| QR12 | HVD-2CL73 | 12KV | 6mA | 100ns |
| TV6 | HVD-2CL70 | 6KV | 5mA | 100ns |
| TV8 | HVD-2CL71 | 8KV | 5mA | 100ns |
| TV10 | HVD-2CL72 | 10KV | 5mA | 100ns |
| TV12 | HVD-2CL73 | 12KV | 5mA | 100ns |
| TV14 | HVD-2CL74 | 14KV | 5mA | 100ns |
| TV16 | HVD-2CL75 | 16KV | 5mA | 100ns |
| TV20 | HVD-2CL77 | 20KV | 5mA | 100ns |
| TVR30 | HVD-2CL82 | 30KV | 10mA | 100ns |
| RUSH103 | HVD-SL200UF3 | 3KV | 200mA | 50ns |
| RUSH104 | HVD-SL200UF4 | 4KV | 200mA | 50ns |
| RUSH105 | HVD-SL200UF5 | 5KV | 200mA | 50ns |
| VT1000 | HVD-SL1000 | 10KV | 50mA | / |
| VT1200 | HVD-SL1200 | 12KV | 50mA | / |
| VT1500 | HVD-SL1500 | 15KV | 50mA | / |
| RVT1000 | HVD-SL10G50 | 10KV | 50mA | 100ns |
| RVT1200 | HVD-SL12G50 | 12KV | 50mA | 100ns |
| RVT1500 | HVD-SL15G50 | 15KV | 50mA | 100ns |
| RUST2008 | — | 8KV | 100mA | 50ns |
| RUST2010 | — | 10KV | 100mA | 50ns |
| CRVT150 | HVD-SL15G25B | 15KV | 25mA | 100ns |
| CRVT200 | HVD-SL20G25B | 20KV | 25mA | 100ns |
| CRVT250 | HVD-SL25G25B | 25KV | 25mA | 100ns |
| CRVT300 | HVD-SL30G25B | 30KV | 25mA | 100ns |
| SL300 | HVD-SL3G40 | 3KV | 40mA | 100ns |
| SL500 | HVD-SL5G40 | 5KV | 40mA | 100ns |
| SL800 | HVD-SL8G40 | 8KV | 40mA | 100ns |
| SL1000 | HVD-SL10G40 | 10KV | 40mA | 100ns |
| SL1200 | HVD-SL12G40 | 12KV | 40mA | 100ns |
| SR300 | HVD-SL3G25 | 3KV | 25mA | 100ns |
| SR500 | HVD-SL5G25 | 5KV | 25mA | 100ns |
| SR800 | HVD-SL8G25 | 8KV | 25mA | 100ns |
| SR1000 | HVD-SL10G25 | 10KV | 25mA | 100ns |
| SR1200 | HVD-SL12G25 | 12KV | 25mA | 100ns |
| SR1500 | HVD-SL15G25 | 15KV | 25mA | 100ns |
| 2CL69 | HVD-2CL69 | 4KV | 5mA | 100ns |
| 2CL70 | HVD-2CL70 | 6KV | 5mA | 100ns |
| 2CL71 | HVD-2CL71 | 8KV | 5mA | 100ns |
| 2CL72 | HVD-2CL72 | 10KV | 5mA | 100ns |
| 2CL73 | HVD-2CL73 | 12KV | 5mA | 100ns |
| 2CL74 | HVD-2CL74 | 14KV | 5mA | 100ns |
| 2CL75 | HVD-2CL75 | 16KV | 5mA | 100ns |
| 2CL76 | HVD-2CL76 | 18KV | 5mA | 100ns |
| 2CL77 | HVD-2CL77 | 20KV | 5mA | 100ns |
| 2CL103 | HVD-2CL103 | 9KV | 350mA | / |
| 2CL104 | HVD-2CL104 | 12KV | 350mA | / |
| 2CL105 | HVD-2CL105 | 9KV | 450mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450mA | / |
| R3000 | HVD-R3000 | 3KV | 200mA | / |
| R3000F | HVD-R3000F | 3KV | 200mA | / |
| R4000 | HVD-R4000 | 4KV | 200mA | / |
| R4000F | HVD-R4000F | 4KV | 200mA | / |
| R5000 | — | 5KV | 200mA | / |
| R5000F | HVD-R5000F | 5KV | 200mA | / |
| RFC3K | HVD-R3000 | 3KV | 200mA | / |
| RFC4K | HVD-R4000 | 4KV | 200mA | / |
| 2CL4 | HVD-2CL69 | 4KV | 5mA | 100ns |
| 2CL6 | HVD-2CL70 | 6KV | 5mA | 100ns |
| 2CL8 | HVD-2CL71 | 8KV | 5mA | 100ns |
| 2CL10 | HVD-2CL72 | 10KV | 5mA | 100ns |
| 2CL12 | HVD-2CL73 | 12KV | 5mA | 100ns |
| 2CL14 | HVD-2CL74 | 14KV | 5mA | 100ns |
| 2CL16 | HVD-2CL75 | 16KV | 5mA | 100ns |
| 2CL20 | HVD-2CL77 | 20KV | 5mA | 100ns |
| 2CL703 | HVD-2CL703 | 3KV | 5mA | 80ns |
| 2CL704 | HVD-2CL704 | 4KV | 5mA | 80ns |
| T71A | HVD-2CLT71 | 8KV | 5mA | 80ns |
| T72A | HVD-2CLT72 | 10KV | 5mA | 80ns |
| T73A | HVD-2CLT73 | 12KV | 5mA | 80ns |
| T74A | HVD-2CLT74 | 14KV | 5mA | 80ns |
| T75A | HVD-2CLT75 | 16KV | 5mA | 80ns |
| TG3508 | HVD-SL3508G | 8KV | 350mA | 150ns |
| TS01 | HVD-SL3506 | 6KV | 350mA | / |
| UX-C2B | — | 8KV | 500mA | 35ns |
| T3512H | HVD-2CL3512 | 12KV | 350mA | / |
| T4512H | HVD-2CL4512 | 12KV | 450mA | / |
| T3509 | HVD-2CL3509 | 9KV | 350mA | / |
| T4509 | HVD-2CL4509 | 9KV | 450mA | / |
| 2CL3512H | HVD-2CL3512 | 12KV | 350mA | / |
| 2CL4512H | HVD-2CL4512 | 12KV | 450mA | / |
| BR2 | HVD-SL2 | 2KV | 1000mA | / |
| BR4 | HVD-SL4 | 4KV | 1000mA | / |
| TG1015 | HVD-2CL15KV / 100 mA | 15KV | 100mA | 150ns |
| SHV049 | HVD-2CL15KV / 100 mA | 15KV | 100mA | 150ns |
| 2CLG1015 | HVD-2CL15KV / 100 mA | 15KV | 100mA | 150ns |
| DD2000 | HVD-SL30F10 | 30KV | 10mA | / |
| JB99 | HVD-2CL20KV / 20 mA | 20KV | 20mA | 100ns |
| JB99T | HVD-2CL20KV / 20 mA | 20KV | 20mA | 100ns |
VRRM = Wiederholte Rückspannung · IO = Durchschnittlicher Ausgangsstrom · trr = Maximale Rückwärtserholungszeit
Marktstatus: HVCA (Dean Technology) ist weiterhin über den Vertrieb erhältlich, allerdings mit langen Lieferzeiten und einem deutlichen Markenaufschlag. HVC bietet eine gleichwertige Alternative zu Direktpreisen ab Werk an, Standardprogramme sind innerhalb von zwei Wochen verfügbar.
ERSATZLÖSUNG.
HVCA, EDI, HVC-Kondensator, HVC-Kondensator und HVC-Kondensator Ich habe eine Reihe von Tests durchgeführt, um die Entwicklung von EDI- und HVCA-Lösungen zu unterstützen Das ist alles Strom- und Spannungsversorgung (1 kV bis 35 kV). 발표했습니다. Im Jahr 2018 wurde ein HVC-Kondensator entwickelt, der die HV-Kondensatoren und die HV-Kondensatoren in den letzten Jahren auf den Markt gebracht hat 많은 프로젝트를 맡고 있습니다. Die HVC-Technologie ist in der Lage, die Sicherheit zu gewährleisten. Weitere Informationen finden Sie unter EDI, HVCA und anderen Anbietern 있습니다. HVC Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs- und Hochspannungs-Spannungsbauweise 500 kV, 10 mA, 20 A, 35 ns, 2,000 Hz, 사용 주파수는 50 Hz oder 200 kHz. Die HVC-Funktion ist in der aktuellen Version verfügbar. 1) 낮은 누설 전류, 서지 전류, 낮은 역방향 전압, 낮은 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 4) 4) 5) 6) 6) 6) 6) 4) 높은 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C 지역과 남동부 지역에 생산 근거지를 두고 있습니다. 10.01.2019 19.09.2019 Die gewünschte Einstellung wird angezeigt, wenn Sie die gewünschte Funktion verwenden. 다음은 자주 검색되는 고전압 다이오드 부품 번호입니다. Die HVC-Funktion ist in der Lage, die Leistung zu steigern und die Leistung zu steigern. 1) 2CL2FL, 2CL2FM, 2CL2FP, 15 kV oder 30 kV, 100 mA oder 140 mA. HVCA- und EDI-Verbindungen, HVCA- und EDI-Verbindungen, HVCA- und EDI-Verbindungen, 초고주파 전송 전원 치치, 먼지 제주파 전송 전원 전원 니니다. Die HVC-Software hat die höchste Priorität des Unternehmens. 2) VT1500, RVT1000, RVT1200, RVT1500, HVRT300, HVRT120, HVRT150, HVRT200, HVCA-Modell. 3) 2CL77, 20 kV, 5 mA, 2CL70, 2CL71, 2CL72, 2CL75, 2CL79, EDI-Verbindung, HVC-Verbindung. 4) UX-F0B, UX-C2B, UX-F15B, UX-F30B, UX-F2CL15, UX-FOB. Die UX-FOB-Funktion ist nicht verfügbar. Der VRRM 8kV-Standard ist ebenfalls verfügbar. „UX“ ist eine 40-ns-Version der aktuellen Version. 이것은 엑스레이 생성기에 대해 높은 반응 및 높은 효율성을 의미합니다. Maximale Auflösung: 300 kHz, maximale Auflösung: 20 Sekunden. UX-C2B ist ein leistungsstarkes 8-kV- und 500-mA-Netzteil mit 500-mA-Anschluss 사용되고, 대표적인 모델은 파나소닉의 전자레인지입니다. Die HVCA-Zulassung ist nicht möglich. Die HVC-Funktion ist für die Verwendung mit UX-C2B und die damit verbundene Leistung geeignet. 5) RFC4K, RFC3K, R3000, R4000, R5000, R3000F, R4000F, R5000F, T2060, T0504, HVC 제공. 6) TV-Show, TV-Show, TV-Show, TV-Show, TV-Show, TV-Show, TV-Show, 레이저에 주로 사용됨. 2CL70, 2CL71, 2CL72, 2CL73, 2CL74, 2CL75, 2CL76, 2CL77, 2CL4, 2CL6, 2CL8, 2CL10, 2CL12,2CL14,2CL16,2CL20,2CL703,2CL704,T71A,T72A,T73A,T74A,T75A,T77 7) 제습기와 같은 가정용 소형 전자 기기와 복사기, 레이저, 네온광 전원 xnxx TG3508, TS01, UX-C2B, T3512H, T4512H, T3509, T4509, 2CL3512H, 2CL4512H, HVM12, HVM15, 2CL103, 2CL104, HVRT080, HVRT120, HVRT150, HVRT300, T0504, 2CLG3512, FR02-60, CL01-12 8) 매연 정화 치치, 전기 집진기에 주로 사용됨. 2CL2FF, 2CL2FG, 2CL2FH, 2CL2FJ, 2CL2FK, 2CL2FL, 2CL2FM, 2CL2FP, HV37-08, HV37-20, BR2, BR4. CL-, BR-, HVRT-, HVRL-, TG1015-, SHV049-, 2CLG1015-, DD2000-, JB99T-, HVRT200- und HVCA-, EDI- und andere Netzwerkverbindungen Die HVC-Familie hat sich für die Zukunft entschieden 니 다.
TYPISCHE ANWENDUNGEN.
Laser-Netzteile
CO₂- und Festkörperlaser-Ladeschaltungen der 6-kV-Klasse.
Elektrostatische Kontrolle
Stromversorgung für elektrostatische Abscheidung und Elektrofilter.
Forschung & Instrumentierung
Kundenspezifische Hochspannungsmultiplikatoren für Labor- und Universitätssysteme.
FAQ.
Kann HVC die Modelle DV6P, DV8P, DV10P, G6FS, G7FS und G8FS ersetzen?
Ja – HVC bietet pinkompatible Direktersatzteile für DV6P, DV8P, DV10P, G6FS, G7FS und G8FS mit identischer Bauform sowie übereinstimmenden Spannungs- und Stromstärkewerten. Jedes Bauteil wird auf Impulsfestigkeit mit dem 1.6-Fachen der Nennspannung geprüft.
Wie lange sind Lieferzeit und Mindestbestellmenge für DV6P?
Standard-Diodenprogramme sind innerhalb von 2 Wochen verfügbar, Musterbestellungen sind ohne Mindestbestellmenge möglich. Die Mindestbestellmenge für die Produktion ist flexibel – kontaktieren Sie unseren Vertrieb für Ihre individuellen Anforderungen.
Wie kann ich überprüfen, ob das Ersatzteil zu meinem Schaltkreis passt?
Fordern Sie ein kostenloses Muster an und testen Sie es im laufenden Betrieb, bevor Sie es einsetzen. HVC stellt Datenblätter und Querverweisdokumentationen für jedes Ersatzteil bereit.
WEITERE ANLEITUNGEN ZUM AUSTAUSCH VON HLK-KABELN.
Hochspannungsdiodenhersteller | 10 kV–30 kV Hochspannungsgleichrichter | Alternative zu HVCA, EDI, VMI
Leitfaden ansehen →
Alternativer Ersatz für HVCA-HV-Diode von UFHV2K UFHV3K UFHV4K
Leitfaden ansehen →
Alternativer Ersatz für HVCA-HV-Diode von HV550S15 HV550S20 HV550S25 HV550S30 HV550S45 HVCF25 HVCF50
Leitfaden ansehen →
Alternativer Ersatz für die HVCA-HV-Diode von 2CL2FP 2CL2FR 2CL105 2CL106
Leitfaden ansehen →
Technische Leitfäden & Querverweise
WEITERFÜHRENDE LITERATUR.
2026-11-08
Dioden-Sperrverzögerungs-Snubber-Dimensionierung für Plasma-Chopper
Bei einer Taktfrequenz von 50 kHz, einer gespeicherten Ladung von 1 µC und einer Sperrspannung von 600 V ergeben sich Erholungsverluste von 0.15 mJ pro Ereignis bzw. 7.5 W innerhalb einer Diode. Durch sanfte Erholung, eine Kommutierungsinduktivität von 4 µH und einen 33 nF / 3 Ω N4700-Snubber wird der Abschaltimpuls von 282 V auf 28 V reduziert.
Leitfaden lesen →
2026-11-08
Dynamische Diodenimpedanz in Plasmazündklemmennetzwerken
Eine Klemmdiode ändert ihren Widerstand von 26 Ω bei 1 mA Vorspannung auf 53 mΩ bei 10 A. Daher überschwingt ein auf einen bestimmten Wert abgestimmtes Netzwerk am Rand und schwingt am Ende. Durch die Zuordnung von r_d(I), die Fixierung des Ruhestroms bei 1 mA Vorspannung und einen stabilen N4700-Kondensator wird die Klemmung innerhalb von ±5 % gehalten.
Leitfaden lesen →
2026-11-07
Gemeinsame Auslegung von Leckage- und Isolationsmaßnahmen für medizinische Plasmaanlagen
Die Leckströme des Patienten stellen ein Kapazitätsproblem dar: Der Grenzwert von 10 µA erlaubt 138 pF bei 230 V und 50 Hz, und ein einzelner 2.2 nF Y-Kondensator zieht 159 µA. Eine 49 pF + 49 pF + 22 pF + 18 pF-Aufteilung, die bei 264 V und 60 Hz geprüft wurde, erfüllt sowohl die Leckstrom- als auch die kV-Festigkeitsanforderungen.
Leitfaden lesen →
2026-11-07
Spannungsspitzenbegrenzung mit Freilaufdioden und Keramikkondensatoren
Eine 2 mH Pilotdrossel, die bei 50 A innerhalb von 1 µs unterbrochen wird, erreicht eine Spannung von 100 kV. Daher benötigt jeder Abschaltvorgang einen definierten Pfad. Um 0.5 mJ innerhalb einer 720-V-Decke zu halten, werden 6.31 nF mit einem 7.96 Ω Dämpfungswiderstand benötigt. Ein zusätzliches Bauteil mit 20 mΩ verursacht lediglich eine Überschwingspannung von 2 V.
Leitfaden lesen →